  • 產(chǎn)品名稱(chēng):Vermason 222547校準(zhǔn)器

  • 產(chǎn)品型號(hào):用于校準(zhǔn)手腕帶和工鞋接地測(cè)試儀
  • 產(chǎn)品廠商:其它品牌
  • 產(chǎn)品文檔:
你添加了1件商品 查看購(gòu)物車(chē)
簡(jiǎn)單介紹:
Vermason 222547校準(zhǔn)器 Calibration Unit for Vermason Wrist Strap and Footwear Tester用于校準(zhǔn)手腕帶和工鞋接地測(cè)試儀適配儀器:222504, 222506,222507, 222562, 222563, 222564, 222565,Vermason(DESCO子品牌)
詳情介紹:

Vermason 222547校準(zhǔn)器 Calibration Unit for Vermason Wrist Strap and Footwear Tester
用于校準(zhǔn)手腕帶和工鞋接地測(cè)試儀
適配儀器:222504, 222506,222507, 222562, 222563, 222564, 222565
Vermason(DESCO子品牌)

Operation
The Tester Calibration Unit was specifically designedfor use in calibration of Vermason brand equipment.The following procedures will not cover adjustment of
the test equipment. For detailed information regardingadjustment of specific Vermason brand testers, pleasecontact Desco Europe Customer Service.

Frequency of recalibration should be based on thecritical nature of those ESD sensitive items handled andthe risk of failure for the ESD protective equipment andmaterials. In general, we recommend that calibration be
performed annually.

Testing the Compact Tester
WRIST STRAP CIRCUIT
1. Connect the 10 mm lead from the Calibration Unitto the wrist strap stud on the Compact Tester.
2. Select 715K FAIL LOW on the Calibration Unit.
3. Press and hold the Calibration Unit’s test probeon the Compact Tester’s test plate. The testershould indicate a FAIL LOW condition.
4. Select 785K PASS LOW on the Calibration Unitand repeat the test. The tester should indicate aPASS condition.
5. Select 33M PASS HIGH on the Calibration Unitand repeat the test. The tester should indicate aPASS condition.
6. Select 37M FAIL HIGH on the Calibration Unitand repeat the test. The tester should indicate aFAIL HIGH condition.

FOOTWEAR CIRCUIT
1. Connect the 10 mm lead from the Calibration Unitto the 10 mm footwear stud on the Compact Tester.
2. Select 715K FAIL LOW on the Calibration Unit.
3. Press and hold the Calibration Unit’s test probeon the Compact Tester’s test plate. The testershould indicate a FAIL LOW condition.
4. Select 785K PASS LOW on the Calibration Unitand repeat the test. The tester should indicate aPASS condition.
5. Select 33M PASS HIGH on the Calibration Unitand repeat the test. The tester should indicate aPASS condition.
6. Select 37M FAIL HIGH on the Calibration Unit andrepeat the test. The tester should indicate aFAIL HIGH condition

姓名:
電話:
您的需求:
 
亚洲国产精品无码久久| 亚洲综合区图片小说区| 国产精品18久久久久久vr| 日本在线一区二区不卡视频 | 国产国拍精品亚洲av片| 好深 好顶视频在线观看| 国产精品久久久久久伊人| 免费午夜福利视频在线看| 性欧美老妇乱码一区二区| 男女成人亚洲精91品在线| 亚洲无线码中文字幕在线| 波多野结衣一区二区无码| 日韩欧美国产欧美在线观看| 久久久久久一区二区三区四| 中文精品久久久久国产。 | 99精品国产一区二区香蕉| 人妻聚色窝窝人体www一区| 一本久道久久综合久久鬼色| 日本精品人妻一区二区三区| 久久国产精品久久喷水| 久久久精品中出内射少妇| 欧美成人午夜福利小视频| 成人无码一区二区三区| 国产十八禁视频在线网站| 暗交小拗女一区二区三区| 国产av综合一区二区三区| 女生操鸡鸡视频在线观看| 欧美高清一级片在线观看| 国产精品久久久久一区二区三区| 极品少妇xxoo无码播放| 亚洲成人中文字幕在线电影| 嫩草影院网站无码进入。| 天天操天天爱天天操天天爱| 久久久婷婷五月亚洲97号色| 67194成人在线视频| 免费中文字幕一区二区三 | 一本久道久久丁香狠狠躁| 手机在线的a站免费观看| 欧美日韩一区二区综合另类| 精品少妇嗷嗷叫在线观看| 国产美女在线永久免费网站|